Poster + Presentation + Paper
15 February 2021 Investigation of the efficacy of a data-driven CT artifact correction scheme for sparse and truncated projection data for intracranial hemorrhage diagnosis
Author Affiliations +
Conference Poster
Abstract
Data-driven CT-image reconstruction techniques for truncated or sparsely acquired projection data to reduce radiation dose, iodine volume, and patient motion artifacts have been proposed. These approaches have shown good performance and preservation of image quality metrics. To continue these efforts, we investigated whether these techniques affect the performance of a machine-learning algorithm to identify the presence of intracranial hemorrhage (ICH). Ten-thousand head CT scans were collected from the 2019 RSNA Intracranial Hemorrhage Detection and Classification Challenge dataset. Sinograms were simulated and then resampled in both a one-third truncated and onethird sparse manner. GANs were tasked with correcting the incomplete projection data in two ways. Firstly, in the sinogram domain, where the incomplete sinogram was filled by the GAN and then reconstructed. Secondly, in the reconstruction domain, where the incomplete data were first reconstructed and the sparse or truncation artifacts were corrected by the GAN. Eighty-five hundred images were used for artifact correction network training, and 1500 were withheld for network assessment via an already trained machine-learning algorithm tasked with diagnosis of ICH presence. Fully-sampled reconstructions were compared with the sparse and truncated reconstructions for classification accuracy. Difference in classification accuracy between the fully sampled (83.4%), sparse (82.0%), and truncated (82.3%) reconstructions was minimal, demonstrating that the network diagnosis performance is unaffected by 2/3 reduction of projection data. This work indicates that data-driven reconstructions for a sparse or truncated projection dataset can provide high diagnostic performance for ICH detection at a fraction of the typical radiation dose.
Conference Presentation
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Alexander R. Podgorsak, Mohammad Mahdi Shiraz Bhurwani, and Ciprian N. Ionita "Investigation of the efficacy of a data-driven CT artifact correction scheme for sparse and truncated projection data for intracranial hemorrhage diagnosis", Proc. SPIE 11595, Medical Imaging 2021: Physics of Medical Imaging, 1159542 (15 February 2021); https://doi.org/10.1117/12.2580899
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Gallium nitride

Reconstruction algorithms

Computed tomography

Data acquisition

Diagnostics

Head

Image quality

Back to Top