28 July 1989 8 Kev X-Ray Zone Plates
Author Affiliations +
Abstract
Sputtered-sliced transmissive x-ray zone plates consisting of concentric rings of Al and Cu have been fabricated and tested using the 8.04 keV k-a line from Cu. Due to the need for high aspect ratios for this 1.54 A radiation, magnetron sputtering onto a rotating opaque central wire was chosen as the fabrication method. Both the fabrication technology and initial results are presented.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. M. Bionta, R. M. Bionta, E. Ables, E. Ables, O. Clamp, O. Clamp, O. D. Edwards, O. D. Edwards, P. C. Gabriele, P. C. Gabriele, D. Makowiecki, D. Makowiecki, L. L. Ott, L. L. Ott, K. M. Skulina, K. M. Skulina, N. Thomas, N. Thomas, } "8 Kev X-Ray Zone Plates", Proc. SPIE 1160, X-Ray/EUV Optics for Astronomy and Microscopy, (28 July 1989); doi: 10.1117/12.962622; https://doi.org/10.1117/12.962622