Presentation + Paper
5 March 2021 Mirau-type full-field optical coherence tomography
Tuan-Shu Ho, Ming-Rung Tsai, Hung-Sheng Chang, Chih-Wei Lu
Author Affiliations +
Abstract
Dynamic-focusing optical coherence tomography (OCT) can provide ~1-μm isotropic resolution in extended depth of field, and Mirau design is preferred because of lower weight. In previous works, we reported a Mirau-type OCT based on high-radiance spatially-incoherent source. However, the illumination intensity is limited by the etendue. Besides, coherent artifacts increases with the partially coherent illumination scheme. In this report, we introduce a method to narrow illumination linewidth to 5 μm and reduce coherence area to 1 μm2. With spatially incoherent illumination, optimized throughput and low-weight design, low-speckle B-scan can be acquired within 0.25 second.
Conference Presentation
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tuan-Shu Ho, Ming-Rung Tsai, Hung-Sheng Chang, and Chih-Wei Lu "Mirau-type full-field optical coherence tomography", Proc. SPIE 11630, Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XXV, 116301F (5 March 2021); https://doi.org/10.1117/12.2582894