Poster + Paper
4 April 2022 Energy optimisation of propagation-based phase-contrast computed tomography: a quantitative image quality assessment
Author Affiliations +
Conference Poster
Abstract
Purpose: This study aims at establishing the optimum x-ray energy for synchrotron acquired propagation-based computed tomography (PB-CT) images to obtain highest radiological image quality of breast mastectomy samples. It also examines the correlation between objective physical measures of image quality with subjective human observer scores to model factors impacting visual determinants of image quality. Approach: Thirty mastectomy samples were scanned at Australian Synchrotron’s Imaging and Medical Beamline. Samples were scanned at energies of 26, 28, 30, 32, 34, and 60 keV at a standard dose of 4mGy. Objective physical measures of image quality were assessed using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), SNR/resolution (SNR/res), CNR/resolution (CNR/res) and visibility. Additional calculations for each measure were performed against reference absorption-based computer tomography (AB-CT) images scanned at 32 keV and 4mGy. This included differences in SNR (dSNR), CNR (dCNR), SNR/res (dSNR/res), CNR/res (dCNR/res), and visibility (dVis). Physical measures of image quality were also compared with visual grading analysis data to determine a correlation between observer scores and objective metrics. Results: For dSNR, dCNR, dSNR/res, dCNR/res, and dVis, a statistically significant difference was found between the energy levels. The peak x-ray energy for dSNR and dSNR/res was 60 keV. For dCNR and dCNR/res 34 keV produced the highest measure compared to 28 keV for dVis. Visibility and CNR correlate to 56.8% of observer scores. Conclusion: The optimal x-ray energy differs for different objective measures of image quality with 30-34 keV providing optimum image quality for breast PB-CT. Visibility and CNR correlate highest to medical imaging expert scores.
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Belinda Lim, Sarah Lewis, Benedicta D. Arhatari, Yakov I. Nesterets, Sheridan C. Mayo, Darren Thomposon, Jane Fox, Beena Kumar, Daniel Hausermann, Anton Maksimenko, Christopher Hall, Matthew Dimmock, Darren Lockie, Mary Rickard, Nicola Giannotti, Andrew Peele, Harry M. Quiney, Timur E. Gureyev, Patrick C. Brennan, and SeyedamirTavakoli Taba "Energy optimisation of propagation-based phase-contrast computed tomography: a quantitative image quality assessment", Proc. SPIE 12031, Medical Imaging 2022: Physics of Medical Imaging, 120313O (4 April 2022); https://doi.org/10.1117/12.2608596
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image quality

X-rays

Breast

Signal to noise ratio

X-ray imaging

Quality measurement

Visualization