17 May 2022 Evaluation of scintillation detectors for ultrahigh dose-rate x-ray beam dosimetry
Shahirah Shaharuddin, Alexander Hart, Magdalena Bazalova-Carter, Luc Beaulieu, Cloe Giguere, Christoph Kleefeld, Mark J. Foley
Author Affiliations +
Abstract
FLASH-Radiotherapy (FLASH-RT) is an emerging radiotherapy technique delivering ionizing radiation beam at ultrahigh dose rates (UHDR), typically ≥40 Gy/s. Animal studies have demonstrated the safety and efficacy of the technique in killing tumor cells while significantly reducing radiation toxicity in normal tissues, compared to conventional radiotherapy (dose-rate exposure <0.03 Gy/s). A reliable real-time dosimeter system is crucial for the characterization of the so-called ‘FLASH-effect’ and an accurate beam delivery. Standard dosimeters for conventional radiotherapy saturate at this high-intensity field or cannot provide real-time measurements. In previous work, optical fiber inorganic scintillating detectors (ISDs) showed excellent linearity with shutter exposure time and tube current, indicating scintillating signals independent of the dose and dose rate, respectively. This study aims to benchmark the performance of the ISD with plastic scintillating detectors (PSDs) for an ultrahigh dose-rate x-ray beam irradiation. Relative scintillator output, signal linearity with dose and dose rate, signal-to-noise ratio (SNR), signal stability and reliability were evaluated for all detectors. In a UHDR x-ray beam irradiation, the ISDs produced a larger SNR than the PSDs. All detectors showed good linearity with tube current (R2 < 0.975) and shutter exposure (R2 >0.999). Gd2O2S:Tb showed excellent repeatability (coefficient of variation (CV) <0.1%) compared to other detectors, while the PSDs resulted in the highest reliability for a UHDR beam measurement with a CV of <0.1%. A further investigation regarding the positioning uncertainty of the ISDs during irradiation due to the detector’s angular dependency and the optimal design of the scintillator detectors for UHDR applications are required.
Conference Presentation
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Shahirah Shaharuddin, Alexander Hart, Magdalena Bazalova-Carter, Luc Beaulieu, Cloe Giguere, Christoph Kleefeld, and Mark J. Foley "Evaluation of scintillation detectors for ultrahigh dose-rate x-ray beam dosimetry", Proc. SPIE 12139, Optical Sensing and Detection VII, 121390L (17 May 2022); https://doi.org/10.1117/12.2621591
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Scintillators

Signal detection

X-rays

Lanthanum

X-ray detectors

Gadolinium

RELATED CONTENT

Optimization of a high resolution real time solid state x...
Proceedings of SPIE (December 30 2003)
Megalopinakophobia: its symptoms and cures
Proceedings of SPIE (June 28 2001)
The use of small x ray detectors for deep space...
Proceedings of SPIE (October 15 2012)
Solid state VRX CT detector
Proceedings of SPIE (April 25 2000)

Back to Top