Translator Disclaimer
Paper
1 October 1990 Update on objective MRTD measurement
Author Affiliations +
Abstract
Two methods of making an objective measurement of MRTD have been under development. The techniques and some results obtained using different types of thermal imager, are described and discussed. Conclusions are that objective measurement techniques can now usefully replace subjective measurements as a production test.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Thomas L. Williams "Update on objective MRTD measurement", Proc. SPIE 1309, Infrared Imaging Systems: Design, Analysis, Modeling, and Testing, (1 October 1990); https://doi.org/10.1117/12.21786