Abstract
In this paper, double surface pyrometer, one with a preceded reflector and another with a preceded absober, are used to measure on-line true temperatures and emissivities of the oxided steelplate and a kind of paint. The main error in the measurement of emissivities comes from the temperature increase of the thermosensor with the preceded absober.When the temperature of the absorber is 40°C and the temperature of the measured surface is above 400°C, the Systematic relative error measuring emissivity is less 5%.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhi Xie, Guanghui Shan, and Kuiming Gao "Study in measuring the true surface temperature and emissivity of a heated object by means of a thermosensor", Proc. SPIE 1311, Characterization, Propagation, and Simulation of Infrared Scenes, (1 September 1990); https://doi.org/10.1117/12.21856