1 January 1991 Comparison of electro-optic diagnostic systems
Karla G. Hagans, Paul D. Sargis
Author Affiliations +
Abstract
We have examined the componentdevices used in electro-optic transientrecording systems and studied their contributions to system noise levels. This work includes the investigation of three system configurations: a 1300-nm laser diode system an 810-nm Mach-Zehnder system and a 1300-nm hybrid system. As a result of our work we have developed a method of analysis for determining the theoretical noise sources in electro-optic transient recording systems.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Karla G. Hagans and Paul D. Sargis "Comparison of electro-optic diagnostic systems", Proc. SPIE 1346, Ultrahigh- and High-Speed Photography, Videography, Photonics, and Velocimetry '90, (1 January 1991); https://doi.org/10.1117/12.23380