Paper
1 February 1991 Comparison of welding results with stable and unstable resonators
Joachim Franek, Keming Du, Silke Pflueger, Ralf Imhoff, Peter Loosen
Author Affiliations +
Proceedings Volume 1397, 8th Intl Symp on Gas Flow and Chemical Lasers; (1991) https://doi.org/10.1117/12.26010
Event: Eighth International Symposium on Gas-Flow and Chemical Lasers, 1990, Madrid, Spain
Abstract
In order to compare welding performance of stable and unstable resonators an industrial axial-flow CO2 -laser in the 5 kW range has been operated with two stable and one unstable resonator at 5 kW. Along with a beam diagnostic analysis of the beam quality benchmark welding tests have been carried out. The results show, that for stable resonators the beam quality is a measure of the welding performance. However the unstable resonator shows considerable higher welding depth as predicted by beam quality dependency found for stable resonators.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joachim Franek, Keming Du, Silke Pflueger, Ralf Imhoff, and Peter Loosen "Comparison of welding results with stable and unstable resonators", Proc. SPIE 1397, 8th Intl Symp on Gas Flow and Chemical Lasers, (1 February 1991); https://doi.org/10.1117/12.26010
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Resonators

Laser resonators

Transmission electron microscopy

Beam analyzers

Chemical lasers

Diagnostics

High power lasers

RELATED CONTENT

Improving the beam quality of a high power Yb YAG...
Proceedings of SPIE (February 28 2006)
New approach to characterize multimode lasers
Proceedings of SPIE (May 04 1993)
Kurtosis as a tool parameter for laser welding
Proceedings of SPIE (April 17 1995)
Coupled chemical lasers
Proceedings of SPIE (May 04 1993)

Back to Top