Paper
1 September 1991 Recent progress towards multikilowatt output
Elmar Mueller-Horsche, Peter Oesterlin, Dirk Basting
Author Affiliations +
Proceedings Volume 1503, Excimer Lasers and Applications III; (1991) https://doi.org/10.1117/12.46913
Event: ECO4 (The Hague '91), 1991, The Hague, Netherlands
Abstract
Experimental results obtained from a 500 Hz, 750 W average output power XeCl laser are presented. The dynamical behavior of the pulse energy and optical investigations of the discharge volume pointed out the limits of the present design. There are strong indications that acoustic perturbations currently prevent the efficient operation of the module at repetition rates higher than 500 Hz. To pass the 1 kW level, further improvements must be made. Increasing the discharge efficiency from 1.1% to date will reduce the creation of shock waves. An aerodynamically designed flow loop will help to shift the ratio of fan power to excitation power (currently 40 kW and 66 kW, respectively) to more reasonable values. The additional use of pulse compression techniques will simplify the choice of adequate high-voltage switching elements.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Elmar Mueller-Horsche, Peter Oesterlin, and Dirk Basting "Recent progress towards multikilowatt output", Proc. SPIE 1503, Excimer Lasers and Applications III, (1 September 1991); https://doi.org/10.1117/12.46913
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Excimer lasers

Electrodes

Capacitors

Fluctuations and noise

Gas lasers

Head

Magnetism

RELATED CONTENT

200 W spiker-sustainer XeCl laser
Proceedings of SPIE (August 16 1994)
Discharge studies with a high-efficiency XeCl excimer laser
Proceedings of SPIE (February 01 1991)
High Repetition Rate High Power Excimer Lasers
Proceedings of SPIE (April 26 1989)
Parametric study of small volume long pulse x ray preionized...
Proceedings of SPIE (September 01 1991)

Back to Top