Paper
1 December 1990 A Fabry-Perot resonator system for mm-wave dielectric measurements at cryogenic temperatures
R. Heidinger
Author Affiliations +
Proceedings Volume 1514, 15th International Conference on Infrared and Millimeter Waves; 151411 (1990) https://doi.org/10.1117/12.2301447
Event: 15th International Conference on Infrared and Millimeter Waves, 1990, Orlando, FL, United States
Abstract
A measurement system is presented which analyzes between 143 GHz and 146 GHz three consecutive TEMooq modes of a hemispherical Fabry-Perot resonator mounted into a gas flow cryostat. The major factors that determine the accuracy of the observed dielectric parameters are discussed. It is found that low dielectric loss can be measured at a level of tan δ = 10-5 which is exemplified for AI2O3 studied between 90 K and 330 K.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. Heidinger "A Fabry-Perot resonator system for mm-wave dielectric measurements at cryogenic temperatures", Proc. SPIE 1514, 15th International Conference on Infrared and Millimeter Waves, 151411 (1 December 1990); https://doi.org/10.1117/12.2301447
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Resonators

Dielectrics

Mirrors

Temperature metrology

Signal attenuation

Error analysis

Spherical lenses

Back to Top