Paper
1 December 1991 Ophthalmic lenses testing by moiré deflectometry
T. Yonte, J. A. Quiroga, Javier Alda, Eusebio Bernabeu
Author Affiliations +
Abstract
The Moiré Deflectometry has been used with success for determination of refractive index, temperature gradients analysis, topography and parallelism control of surfaces and others, Nowadays it’s been applied this method to oftalmic lenses testing. However the Moiré Deflectometry applied to oftalmic industry need an automatization of the tests, which present some advantages in the quality control process made in industries working with its. In this work we present results of the spherical aberration and astigmatism coefficients, curvature radii and power measures, of different oftalmic lenses. This results are compared with other ones obtained by means of other techniques, in general, more expensive and tedious that Moiré Deflectometry.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
T. Yonte, J. A. Quiroga, Javier Alda, and Eusebio Bernabeu "Ophthalmic lenses testing by moiré deflectometry", Proc. SPIE 1554, Second International Conference on Photomechanics and Speckle Metrology, (1 December 1991); https://doi.org/10.1117/12.57492