1 June 1992 PV006S streak tube for 500-MHz circular-scan operation
Author Affiliations +
Abstract
A modified PV006S image-converter tube is suggested for use as a primary receiver component for laser ranging systems. The design features of the tube itself, its two- dimensional 2 GHz response, and the sensitive deflection system are reviewed. Some experimental results are also presented which indicate that a 500 MHz circular-scan camera prototype has an experimental temporal response function of less than 5 ps in cw mode of operation.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Gennadii I. Bryukhnevich, S. A. Kaidalov, V. V. Orlov, Alexander M. Prokhorov, Yury N. Serdyuchenko, and Mikhail Ya. Schelev "PV006S streak tube for 500-MHz circular-scan operation", Proc. SPIE 1655, Electron Tubes and Image Intensifiers, (1 June 1992); doi: 10.1117/12.60341; https://doi.org/10.1117/12.60341