Paper
22 December 1992 Well-type phoswich counters for low-flux X-ray/gamma-ray detection
Tuneyoshi Kamae, Shuichi Gunji, Masaharu Hirayama, Hidetoshi Kubo, S. Miyazaki, Yoshitaka Saito, Yutaro Sekimoto, Kentaroh Suzuki, Tadayuki Takahashi, Takayuki Tamura, Masaaki Tanaka, Noriko Y. Yamaoka, Takamasa Yamagami, Masaharu Nomachi, Heihachiro Murakami
Author Affiliations +
Abstract
We have developed a new kind of phoswich counters that are capable of detecting low flux hard X-ray/γ-ray from localized sources. The counter consists of a small inorganic scintillator with a fast decay time (the detection part) glued to the interior bottom surface of a well-shaped block of another inorganic scintillator with a slow decay time (the shielding part). The well-shaped shielding part acts as an active collimator as well as an active shield. The whole assembly is viewed by a phototube from the exterior bottom surface of the shielding part. By using an appropriate pulse-shape discriminator (PSD), hard X-rays/gamma-rays that have deposited energy only in the detection part can be selected. The first counter was built by using a new scintillator (GSO) for the detection part and CsI(Tt) for the shielding part. A detector system consisting of 64 such phoswich counters (total area ~740cm2) was flown three times on board a balloon, setting a limit to the 57Co line flux from SN1987A at around 10-4cm-2s, determining the pulsating hard X/γ-ray flux of PSR15O9-58, determining the hard X/γ-ray spectra of CenA and GX339-04. Analyses have revealed the fact that background counts due to the Compton scattering, nuclear reactions, and β-γ radioactivities in the detector are largely suppressed because they are likely to register at least one extra count in the shielding part. The ultimate sensitivity of the detector will then be determined by the level of radioactive contamination. Other scintillator combinations such as GSO/BGO, NaI(Tl)/CsI(Tl), and YAIO3/BGO have also been studied. Efforts to reduce the radioactive contamination in scintillators have also been actively pursued. In near future we expect to reach a sensitivity (3σ) around a few times 10-7cm-2s-1keV-1 for continuum in a 104s balloon observation.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tuneyoshi Kamae, Shuichi Gunji, Masaharu Hirayama, Hidetoshi Kubo, S. Miyazaki, Yoshitaka Saito, Yutaro Sekimoto, Kentaroh Suzuki, Tadayuki Takahashi, Takayuki Tamura, Masaaki Tanaka, Noriko Y. Yamaoka, Takamasa Yamagami, Masaharu Nomachi, and Heihachiro Murakami "Well-type phoswich counters for low-flux X-ray/gamma-ray detection", Proc. SPIE 1734, Gamma-Ray Detectors, (22 December 1992); https://doi.org/10.1117/12.138581
Lens.org Logo
CITATIONS
Cited by 19 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Genetical swarm optimization

Sensors

Crystals

Scintillators

Contamination

Thorium

Gamma radiation

Back to Top