25 February 1993 Calorimetric measurements of power distribution in multipole-wiggler radiation
Author Affiliations +
Abstract
Power density distribution in multipole-wiggler radiation was measured on the beamline BL-28 of the Photon Factory using a photocalorimetric device. The beamline had no beryllium nor graphite windows, which allowed exact comparison between measured power and calculated value using Kim's formula for undulator radiation. Although the measured density was lower by an average 20% at the peak density, it was ascertained that Kim's formula gives roughly the power density of multipole-wiggler radiation. In addition, the photocalorimetry was found to be a useful means for measuring high-power x-radiation.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Mihiro Yanagihara, Mihiro Yanagihara, Yoshinori Goto, Yoshinori Goto, Seiji Asaoka, Seiji Asaoka, Hideki Maezawa, Hideki Maezawa, Hidenao Sugawara, Hidenao Sugawara, } "Calorimetric measurements of power distribution in multipole-wiggler radiation", Proc. SPIE 1739, High Heat Flux Engineering, (25 February 1993); doi: 10.1117/12.140542; https://doi.org/10.1117/12.140542