An experiment was performed on a front-side illuminated CCD to measure its linear diattenuation at 550 nm and 650 nm as a function of angle of incidence. The linear diattenuation of the CCD varies from 0 to 12 percent for 550 nm light from 0 to 40 deg and is less for the longer wavelength.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Apostolos Deslis, Apostolos Deslis, Suzanne Terese Smith, Suzanne Terese Smith, James P. McGuire, James P. McGuire, } "Linear diattenuation of a front-side-illuminated CCD", Proc. SPIE 1746, Polarization Analysis and Measurement, (11 December 1992); doi: 10.1117/12.138804; https://doi.org/10.1117/12.138804