21 January 1993 Cryogenic performance of the SIRTF prototype secondary-mirror assembly
Author Affiliations +
Abstract
Results are presented of the first liquid helium temperature testing of the Space Infrared Telescope Facility (SIRTF) prototype Secondary Mirror Assembly (PSMA). Attention is given to the key requirements of PSMA, its design, and the test instrumentation and procedures. Results of preliminary tests completed to date showed that the design of the PSMA forms a very strong basis for meeting the SIRTF requirements.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Mark T. Stier, Mark T. Stier, John C. Doyle, John C. Doyle, Michael A. Duffy, Michael A. Duffy, Kenneth S. Gottschalck, Kenneth S. Gottschalck, Sarma N. Gullapalli, Sarma N. Gullapalli, Jeffrey W. Neuner, Jeffrey W. Neuner, } "Cryogenic performance of the SIRTF prototype secondary-mirror assembly", Proc. SPIE 1765, Cryogenic Optical Systems and Instruments V, (21 January 1993); doi: 10.1117/12.140881; https://doi.org/10.1117/12.140881