Paper
26 February 1993 High-sensitivity external modulator data link for high-energy particle detector diagnostics
Kent George McCammon, Mark E. Lowry, Yuan-Hann Chang, Paul J. Parker, Bolek Wyslouch, Craig Wuest, Charles F. McConaghy, Ulrich J. Becker
Author Affiliations +
Proceedings Volume 1790, Analog Photonics; (1993) https://doi.org/10.1117/12.141720
Event: Fibers '92, 1992, Boston, MA, United States
Abstract
An analog fiber-optic data link has been demonstrated for direct charge readout of wire chambers used in high energy particle detectors. The fiber link consists of a Nd:YAG laser carrier, a Mach-Zehnder external modulator, and a low-noise optical receiver. A charge pulse developed on a sensing wire flows directly into the electro-optic modulator with no preamplification. The substitution of passive modulators and fiber cable for active electronics and copper wire near large collider detectors has clear advantages with regard to radiation damage susceptibility, EMI immunity, physical size, and power consumption. Also, the modulator performance was unaffected for an applied one Tesla magnetic field. Reduction of noise contributions from the laser carrier and optical receiver and exploitation of the 'effective optical gain' properties of external modulators resulted in shot-noise-limited link sensitivity. Modulators were packaged with large termination resistorsenabling increased charge sensitivity with an increased system risetime tradeoff. Energy resolution of the fiber link was comparable to preamps conditional on large terminations and subsequent slow readout. For shorter risetimes required in timing diagnostics, small termination resulted in sensitivity 6.8 times inferior to preamps. Several potential improvements in sensitivity are discussed.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kent George McCammon, Mark E. Lowry, Yuan-Hann Chang, Paul J. Parker, Bolek Wyslouch, Craig Wuest, Charles F. McConaghy, and Ulrich J. Becker "High-sensitivity external modulator data link for high-energy particle detector diagnostics", Proc. SPIE 1790, Analog Photonics, (26 February 1993); https://doi.org/10.1117/12.141720
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulators

Receivers

Sensors

Diagnostics

Signal to noise ratio

Analog electronics

Electrodes

Back to Top