Paper
1 January 1993 High spatio-temporal resolution x-ray streak cameras with bilamellar tubes: experimental confirmation of the performance
Alain Mens, Dominique Gontier, J.-C. Huilizen, Richard Sauneuf, Daniel Schirmann, Roger Verrecchia, Patrick Audebert, Jean-Claude J. Gauthier, Jean-Paul Geindre, Andre Antonetti, Jean-Paul Chambaret, G. Hamoniaux, Andre Mysyrowicz
Author Affiliations +
Proceedings Volume 1801, 20th International Congress on High Speed Photography and Photonics; (1993) https://doi.org/10.1117/12.145802
Event: 20th International Congress on High Speed Photography and Photonics, 1992, Victoria, BC, Canada
Abstract
High resolution x-ray streak cameras using tubes with bilamellar electron optics have been developed for a long time in CEL-V, in collaboration with Philips Components (now Philips Photonics) for the tubes. The last improvements on their electronics, implemented on the commercial cameras developed with ARP, have allowed us to get the best results from the tubes, especially for the quality of their focusing. We have already been able to verify that the performance of the C850X camera in the UV range is as good as expected from calculations. New experiments made in the x-ray range show that it is also true in the x-ray range. We describe the results of these experiments and we also show preliminary results obtained with the C750X camera (which is identical to C850X except that its deflection structure is a meander travelling wave line instead of conventional plates) which show that the sweep speed reached gives us a 1 ps temporal resolution in the x-ray range.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Alain Mens, Dominique Gontier, J.-C. Huilizen, Richard Sauneuf, Daniel Schirmann, Roger Verrecchia, Patrick Audebert, Jean-Claude J. Gauthier, Jean-Paul Geindre, Andre Antonetti, Jean-Paul Chambaret, G. Hamoniaux, and Andre Mysyrowicz "High spatio-temporal resolution x-ray streak cameras with bilamellar tubes: experimental confirmation of the performance", Proc. SPIE 1801, 20th International Congress on High Speed Photography and Photonics, (1 January 1993); https://doi.org/10.1117/12.145802
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Cameras

Picosecond phenomena

Plasmas

Photonics

Streak cameras

Spatial resolution

RELATED CONTENT

Picosecond Soft X-Ray Streak Camera
Proceedings of SPIE (June 07 1989)
Performance of the ultrafast streak camera C850X
Proceedings of SPIE (January 19 1993)
P 600 650 X Ray Streak Camera With Optimized Spatio...
Proceedings of SPIE (March 01 1983)
Ultrafast one and two dimensional x ray imaging by...
Proceedings of SPIE (April 17 2001)

Back to Top