Paper
14 September 1993 Condensed Monte Carlo simulations applied to reflectance pulse oximetry
Reindert Graaff, A. C. M. Dassel, Marco H. Koelink, Jan G. Aarnoudse, Frits F. M. de Mul, W. G. Zijlstra, Jan Greve
Author Affiliations +
Proceedings Volume 1888, Photon Migration and Imaging in Random Media and Tissues; (1993) https://doi.org/10.1117/12.154637
Event: OE/LASE'93: Optics, Electro-Optics, and Laser Applications in Scienceand Engineering, 1993, Los Angeles, CA, United States
Abstract
In reflectance pulse oximetry the ratio R/IR between the red and infrared intensity fluctuations, as measured at the skin surface, is used to estimate the arterial oxygen saturation. This ratio is influenced by light propagation in tissue, as measurements at several distances between light sources and detectors simultaneously show that R/IR depends on this distance. In the present study the influence of the estimated tissue properties on R/IR and its distance dependence are investigated by means of Monte Carlo simulations, a method to vary the optical properties without the need for a new Monte Carlo simulation. A three wavelength model has been introduced, because of secondary emission of the red LED. The influence of water absorption has been taken into account. The simulation results depend on the chosen optical properties. Results of R/IR for SaO2 equals 98% with properties from in vivo experiments agree much better with the measured values than the predictions based on in vitro data available in literature. The results show that the condensed Monte Carlo simulation is a valuable tool to gain insight in the principles of reflectance pulse oximetry: The model, assuming a homogeneous distribution of pulsations, is able to describe the experimental results for pulse sizes, R/IR and its distance dependence very well.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Reindert Graaff, A. C. M. Dassel, Marco H. Koelink, Jan G. Aarnoudse, Frits F. M. de Mul, W. G. Zijlstra, and Jan Greve "Condensed Monte Carlo simulations applied to reflectance pulse oximetry", Proc. SPIE 1888, Photon Migration and Imaging in Random Media and Tissues, (14 September 1993); https://doi.org/10.1117/12.154637
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monte Carlo methods

Sensors

Oximetry

Absorption

Blood

Reflectivity

Scattering

Back to Top