14 December 1992 Design and experiments of higher cyclotron harmonic peniotron oscillators
Author Affiliations +
Proceedings Volume 1929, 17th International Conference on Infrared and Millimeter Waves; 19296W (1992) https://doi.org/10.1117/12.2298365
Event: 17th International Conference on Infrared and Millimeter Waves, 1992, Pasadena, CA, United States
Abstract
Higher cyclotron harmonic peniotron oscillators with magnetron type cavities have been studied. In the 2nd harmonic experimental tube, the output power of 1.3kW and the highest electronic efficiency of 44% have been ob- tained at 10GHz at the TE3,1,1 resonant mode in the cavity. The 3rd and 10th harmonic experimental tubes were de- signed at 30GHz and 100GHz, respectively. The tubes showed that the electronic efficiencies have 70% and 40% for an ideal electron beam with the velocity ratio of 2 at respective modes of TE433 and TE11,13.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
K. Yokoo, K. Yokoo, } "Design and experiments of higher cyclotron harmonic peniotron oscillators", Proc. SPIE 1929, 17th International Conference on Infrared and Millimeter Waves, 19296W (14 December 1992); doi: 10.1117/12.2298365; https://doi.org/10.1117/12.2298365