Paper
19 October 1993 Sensitivity of a coded-aperture telescope when used with a detector that under-samples the shadowgram
K. Byard, David Ramsden
Author Affiliations +
Abstract
The imaging properties of a gamma-ray telescope which employs a coded aperture in conjunction with a modular detection plane have been investigated. Gaps in the detection plane, which arise as a consequence of the design of the position sensitive detector used, produce artifacts in the deconvolved images. The effect is generally to reduce the signal to noise ratio for the detection of point sources. The application of an iterative image processing algorithm is shown to restore the image quality to that expected from an ideal detector.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
K. Byard and David Ramsden "Sensitivity of a coded-aperture telescope when used with a detector that under-samples the shadowgram", Proc. SPIE 1948, Astroparticle Physics and Novel Gamma-Ray Telescopes, (19 October 1993); https://doi.org/10.1117/12.161372