1 March 1995 Method of measuring active-medium and resonator parameters in sputtered hollow cathode discharge (HCD) He-Cu lasers
Author Affiliations +
Abstract
A new method has been developed for direct measurements of unsaturated and saturated gain in lasing media as well as optical losses in laser resonators. The saturation parameter can be determined if single-frequency laser performance is achieved. This method has been successfully applied to measure and compare lasing features of the media created in sputtered hollow cathode discharge (HCD) copper ion lasers operating on 780.8 nm transition.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tadeusz M. Adamowicz, Tadeusz M. Adamowicz, } "Method of measuring active-medium and resonator parameters in sputtered hollow cathode discharge (HCD) He-Cu lasers", Proc. SPIE 2202, Laser Technology IV: Research Trends, Instrumentation, and Applications in Metrology and Materials Processing, (1 March 1995); doi: 10.1117/12.203746; https://doi.org/10.1117/12.203746