Paper
21 March 1994 New results for prediction of cutting tools wearing resistance using one- and two-side transient thermal NDT method
Vladimir P. Vavilov, V. A. Pushnykh, V. Tsipilev, A. V. Shipulin, Ermanno G. Grinzato
Author Affiliations +
Abstract
This paper contains experimental results obtained by applying both one-side and two-side diffusivity measurement procedure for Russian-made cutting tools. Experimental set included CO2 laser with energy up to 12 J in 4 ms pulse and diffusivity measurement device TAU- 1. In two-side test the correlation coefficient between wear resistance and obtained value of diffusivity was estimated to be K equals -0.61. In one-side test the ratio of signals at 6 and 9 ms after flash was accepted as wear resistance criterion. The corresponding correlation coefficient was K equals 0.59. Some results obtained with Swedish-made tools of unknown composition are also discussed.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vladimir P. Vavilov, V. A. Pushnykh, V. Tsipilev, A. V. Shipulin, and Ermanno G. Grinzato "New results for prediction of cutting tools wearing resistance using one- and two-side transient thermal NDT method", Proc. SPIE 2245, Thermosense XVI: An International Conference on Thermal Sensing and Imaging Diagnostic Applications, (21 March 1994); https://doi.org/10.1117/12.171166
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Resistance

Nondestructive evaluation

Measurement devices

3D modeling

Carbon dioxide lasers

Helium neon lasers

Laser cutting

Back to Top