Abstract
The last results of working out of OW clinotrons are brought. The output power was received by units of watts in short-wave part of millimeter wave band (weight of packed device is 1.2 kg) and hundreds of milliwatts in long-wave part of submillimeter wave band (weight is 12 kg). The compact self-contained cooling system on the basis of heat pipe was created for millimeter clinotrons.