11 November 1994 Focusing of synchrotron x-ray radiation with cylindrically curved arrays of reflectors
Andrei V. Rode, Andrew G. Peele, Keith A. Nugent, Dan E. Johnson, D. Peter Siddons
Author Affiliations +
Abstract
We present results of the experimental tests of various arrays of reflectors acting as X-ray optical elements. Planar reflectors were aligned with a common center of curvature to create a 1D focusing array. The experiments were carried out using X-ray radiation in the spectral range 3.5 keV to 7 keV produced at beamline X-27C of the National Synchrotron Light Source at the Brookhaven National Laboratory. The initial beam had width of 90 mm, a focal distribution had a width of 8 mm and a maximum intensity gain of 7.3, as measured with a 0.4 mm diameter pinhole. An X-ray beamsplitter consisting of arrays of reflectors has also been designed and tested. The separation of X-ray beams is 40 mrad and intensity of each of two beams is about 0.32 of the original X-ray beam.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Andrei V. Rode, Andrew G. Peele, Keith A. Nugent, Dan E. Johnson, and D. Peter Siddons "Focusing of synchrotron x-ray radiation with cylindrically curved arrays of reflectors", Proc. SPIE 2279, Advances in Multilayer and Grazing Incidence X-Ray/EUV/FUV Optics, (11 November 1994); https://doi.org/10.1117/12.193148