Abstract
A thorough investigation of the temperature induced performance errors of IFOG configured fiber gyros was performed. The investigation was focused on low-cost optical components which are capable of being assembled into a gyro package volume of less than two cubic inches including electronics. Testing performed at the optical component level includes diode sources, receivers, wound coils, and integrated optic assemblies. Testing also included the fabrication of IFOG circuits and performing gyro bias and noise measurements. The test results indicate that high performance rate sensing is possible given the use of low cost optical components.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jeffrey L. Duryea, Jeffrey L. Duryea, Jeff Bush, Jeff Bush, } "Environmental test results of low-cost fiber optic rate gyros", Proc. SPIE 2292, Fiber Optic and Laser Sensors XII, (1 November 1994); doi: 10.1117/12.191844; https://doi.org/10.1117/12.191844