12 December 1994 Furniture ergonomics studies by the projection moiré method
Author Affiliations +
Abstract
A new application of human back contouring by the projection moire method for the assessment of furniture design ergonomics is presented. The muscle-osseous system is analyzed in three planes and several characteristic points to find 6 basic parameters selected from 48 automatically analyzed ones for the standing and sitting positions. If the furniture dimensions are incorrectly selected with respect to the user height and body proportions the values of selected parameters differ for the two positions. The analysis indicates, with high accuracy, the places of the vertebral column exposed to the risk of postural deformities in the case of incorrectly chosen furniture.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
I. Nikolowa-Burzynska, I. Nikolowa-Burzynska, A. Mabiala, A. Mabiala, Krzysztof Patorski, Krzysztof Patorski, D. Zawieska, D. Zawieska, } "Furniture ergonomics studies by the projection moiré method", Proc. SPIE 2340, Interferometry '94: New Techniques and Analysis in Optical Measurements, (12 December 1994); doi: 10.1117/12.195944; https://doi.org/10.1117/12.195944
PROCEEDINGS
6 PAGES


SHARE
RELATED CONTENT

A new innovative depth from defocus method identification of...
Proceedings of SPIE (September 01 2016)
Characterizing motility dynamics in human RPE cells
Proceedings of SPIE (February 07 2017)
Space-time feature-specific imaging
Proceedings of SPIE (June 03 2011)
High-speed thermal imaging systems
Proceedings of SPIE (November 10 1993)

Back to Top