10 April 1995 CCDs for spectroscopy
Author Affiliations +
Abstract
CCDs have been used in spectroscopy for a number of years and for all the obvious reasons. Unfortunately most scientific CCDs are square arrays and are not ideally formatted for spectroscopic applications. This paper discuses the design and fabrication of two CCD arrays specifically intended for use in spectroscopic applications. The devices have 1100 X 330 and 1752 X 532 pixel formats, and are fabricated using the three phase, overlapping polysilicon gate technology and they are available in both front-illuminated as well as back- illuminated versions. In addition, devices with enhanced UV sensitivity are being fabricated. Characterization data are presented. The architecture of these devices leads to some interesting applications which we discuss briefly.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yair Talmi, Morley M. Blouke, Taner Dosluoglu, Mark D. Nelson, Raymond W. Simpson, John Stephen West, "CCDs for spectroscopy", Proc. SPIE 2415, Charge-Coupled Devices and Solid State Optical Sensors V, (10 April 1995); doi: 10.1117/12.206524; https://doi.org/10.1117/12.206524
PROCEEDINGS
9 PAGES


SHARE
RELATED CONTENT

New CCD imager for spectroscopy
Proceedings of SPIE (February 15 1994)
Development of the Wide Field Grism Spectrograph 2
Proceedings of SPIE (September 30 2004)
Commissioning and performances of the VLT-VIMOS
Proceedings of SPIE (March 07 2003)

Back to Top