You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
8 May 1995Multiparameter optimization of mammography with alternative x-ray sources
Hamid Jafroudi,1 Robert J. Jennings,2 E. Philip Muntz,3 Matthew T. Freedman M.D.,4 Seong Ki Mun4
1Georgetown Univ. (United States) 2Ctr. for Devices and Radiiological Health/FDA (United States) 3Univ. of Southern California (United States) 4Georgetown Univ. Medical Ctr. (United States)
The conventional x-ray source for mammography, with a molybdenum (Mo) anode and Mo filter, works well for breasts of low to moderate x-ray attenuation, but is not readily adaptable to the production of higher x-ray energies that are more suitable for imaging breasts of higher attenuation. Accordingly, alternative sources with anodes of rhodium (Rh) and tungsten (W) have been developed to improve the efficiency of the examination for thick or radiographically dense breasts. We have applied previously developed multiparameter optimization techniques to imaging systems using these alternative x-ray sources. Since these sources are intended to improve mammography of high-attenuation breasts, optimizations were performed for a range of breast thicknesses. Since high attenuation is generally associated with high scatter, optimizations for each source were done with a high-ratio, air-interspace grid similar to the one developed in our previous work. Preliminary results have been obtained for optimized system configurations using a W-anode source with Mo, Rh, and aluminum (Al) filters, and for a Mo-anode source with Rh filtration. These results indicate that the alternative sources studied can significantly improve the efficiency of mammography of high-attenuation breasts.
The alert did not successfully save. Please try again later.
Hamid Jafroudi, Robert J. Jennings, E. Philip Muntz, Matthew T. Freedman M.D., Seong Ki Mun, "Multiparameter optimization of mammography with alternative x-ray sources," Proc. SPIE 2432, Medical Imaging 1995: Physics of Medical Imaging, (8 May 1995); https://doi.org/10.1117/12.208329