3 July 1995 Repairing x-ray masks with Ta absorbers using focused ion beams
Author Affiliations +
Abstract
A focus ion beam system was used to repair x-ray masks with Ta absorbers. To repair opaque defects, excess Ta is removed by ion milling. Since the wall of the milled pattern is tapered compared to the absorber patterns of the mask, milling parameters such as the ion dose are justified by printing the repaired pattern on the resist with the SR exposure system. Clear repairs are made with Ta deposited using a organometallic material. Since the Ta content of the deposit was about 30%, a Ta deposition layer thicker than 1.2-micrometers is necessary to keep the contrast of the x-rays high. The repaired Ta absorber patterns have high chemical durability and are not damaged by wet cleaning with strong acid. We printed on resists with repaired masks and confirmed that the defects were completely repaired.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ikuo Okada, Ikuo Okada, Yasunao Saitoh, Yasunao Saitoh, Takashi Ohkubo, Takashi Ohkubo, Misao Sekimoto, Misao Sekimoto, Tadahito Matsuda, Tadahito Matsuda, } "Repairing x-ray masks with Ta absorbers using focused ion beams", Proc. SPIE 2512, Photomask and X-Ray Mask Technology II, (3 July 1995); doi: 10.1117/12.212775; https://doi.org/10.1117/12.212775
PROCEEDINGS
6 PAGES


SHARE
RELATED CONTENT

Repair Of Dear Defects On X Ray Masks By Ion...
Proceedings of SPIE (July 31 1989)
Issues in the repair of x-ray masks
Proceedings of SPIE (February 28 1991)
X-ray mask defect repair optimization
Proceedings of SPIE (June 24 1999)
Fib Mask Repair With Microtrim
Proceedings of SPIE (June 29 1986)

Back to Top