Abstract
A 10 MeV linear induction accelerator has been built for use in flash radiography. This machine consists of a 1 MeV injector followed by 28 accelerating induction cells. Each accelerating cell adds 320 kV to the electron beam. An electron beam of 2 kA with focal spot diameter < 4 mm on the target has been obtained. Exposure dose at a distance of 1 meter is 90 R, and the pulse length is 90 ns. In this paper the construction of the accelerator and its operation characteristics are presented.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zucong Tao, Zucong Tao, Shouyun Zhang, Shouyun Zhang, Bonan Ding, Bonan Ding, } "10-MeV linear induction accelerator for flash radiography", Proc. SPIE 2513, 21st International Congress on: High-Speed Photography and Photonics, (30 May 1995); doi: 10.1117/12.209665; https://doi.org/10.1117/12.209665