15 June 1995 Detector calibration at the radiometry laboratory of the Physikalisch-Technische Bundesanstalt in the VUV and soft x-ray spectral ranges using synchrotron radiation
Thomas Lederer, Hans Rabus, Frank Scholze, R. Thornagel, Gerhard Ulm
Author Affiliations +
Abstract
In the vacuum ultraviolet and soft x-ray spectral ranges the radiometry laboratory of the Physikalisch-Technische Bundesanstalt at the synchrotron radiation facility BESSY offers two different methods for the calibration of radiation detectors. The electron storage ring BESSY, in combination with suitable monochromators, reproducible produces monochromatic radiation of tunable photon energy, high spectral purity, and high radiant power which can be reduced by twelve orders of magnitude. With this source of monochromatic radiation a cryogenic electrical substitution radiometer (ESR) is operated as a primary detector standard in the photon energy range from 3 eV to 1500 eV. The ESR is optimized for synchrotron radiation, capable of measuring radiant power in the order of some (mu) W with an uncertainty below 0.2%. Radiation detectors can be calibrated against the ESR with uncertainties well below 1%. Recent progress in this field will be demonstrated for the calibration of photodiodes. The electron storage ring BESSY is also used as a primary source standard, in the photon energy range from the infrared to the soft x-ray range. The spectral and spatial distribution of the broadband radiation, emitted in the range from 1 eV to 15 keV, is calculable from the known storage ring parameters with uncertainties from 0.04% to 0.35%, respectively. This allows the detection efficiency of energy-dispersive detectors such as solid-state detectors, charge- coupled devices, and others to be determined, provided the detector response function to monochromatic radiation is measured as well.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Thomas Lederer, Hans Rabus, Frank Scholze, R. Thornagel, and Gerhard Ulm "Detector calibration at the radiometry laboratory of the Physikalisch-Technische Bundesanstalt in the VUV and soft x-ray spectral ranges using synchrotron radiation", Proc. SPIE 2519, X-Ray and Ultraviolet Sensors and Applications, (15 June 1995); https://doi.org/10.1117/12.211893
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Calibration

Photodiodes

X-rays

Synchrotron radiation

Monochromators

Radiometry

Back to Top