An ultraviolet-sensitive scientific CCD camera has been tested at a power reactor facility to image the faint Cerenkov light from irradiated nuclear fuel. The instrument mates custom optical components (lens, UV-pass filter) to a commercial scientific camera (Astrocam 4100) with a coated frame-transfer CCD chip (EEV 37-10) to produce 12-bit images of 512 X 512 pixels at a near-real-time frame rate. A 250-mm f/2.6 catadioptric lens has been designed with transmissive optics optimized for this application, incorporating color correction for viewing through 10 m of water. The filter has an average transmission of 80% from 280 to 320 nm, with visible-light transmission of less than 0.01% to block artificial lighting in the fuel bay. Measurements were made with this instrument at the Ringhals Nuclear Power Plant, Varobacka, Sweden. Both fuel and non-fuel assemblies of boiling-water reactor type were studied. Performance is superior to that of the earlier Cerenkov viewing devices based on image intensifier tubes. Increased sensitivity extends the range of the Cerenkov verification technique to fuel with older discharge dates. Increased resolution allows fine details of the fuel to be examined for higher-confidence safeguards verification. Sample digital images are presented, and the advantages to irradiated-fuel verification of image quantitation, storage, transmission, and processing are discussed.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
E. Michael Attas, E. Michael Attas, G. R. Burton, G. R. Burton, J. Dennis Chen, J. Dennis Chen, Lars Hildingsson, Lars Hildingsson, A. Nilsson, A. Nilsson, O. Trepte, O. Trepte, Gary J. Young, Gary J. Young, } "Ultraviolet digital imaging for nuclear safeguards", Proc. SPIE 2654, Solid State Sensor Arrays and CCD Cameras, (25 March 1996); doi: 10.1117/12.236110; https://doi.org/10.1117/12.236110
PROCEEDINGS
12 PAGES


SHARE
RELATED CONTENT

VUV testing of science cameras at MSFC QE measurement...
Proceedings of SPIE (August 24 2015)
Technological developments of the OGRE focal plane array
Proceedings of SPIE (September 18 2015)
A Comparison Of Machine Vision Sensors
Proceedings of SPIE (November 14 1988)
The evolution of the scientific CCD
Proceedings of SPIE (February 16 2011)
A 1024 Pixel CCD Line Scan Image Sensor With Color...
Proceedings of SPIE (November 08 1984)
The Hubble CCDs: lessons learned
Proceedings of SPIE (August 25 2005)

Back to Top