Abstract
A nondestructive technique for the quantitative evaluation of defects in metal structures is described. The surface of the metal is irradiated by a short xenon lamp pulse and monitored by a thermal image processor. The analysis relates to the time decay signal of the front face temperature, which contains information on the thermophysical properties and subsurface defects of the material. The time history of the surface temperature is then used to quantify the substructure of the material. Applications for the inspection of aluminum, steel, and turbine blades are presented.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Arnold Daniels, Arnold Daniels, } "Nondestructive pulsed infrared quantitative evaluation of metals", Proc. SPIE 2766, Thermosense XVIII: An International Conference on Thermal Sensing and Imaging Diagnostic Applications, (15 March 1996); doi: 10.1117/12.235375; https://doi.org/10.1117/12.235375