25 September 1996 Measurement of noise of photovoltaic HgCdTe and InSb infrared detector
Author Affiliations +
Abstract
An investigation of noises in two linear detector has been described in this paper. Noises were measured at 80 K from 10 - 100 KHz at different reverse bias. In all samples of HgCdTe and InSb. 1/f noises were observed. In order to decrease 1/f noise, processing needs improving further. The various noises have been discussed.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhongyun Tian, Ruoxi Ji, Shengqiong Lei, Boqi Gu, "Measurement of noise of photovoltaic HgCdTe and InSb infrared detector", Proc. SPIE 2894, Detectors, Focal Plane Arrays, and Applications, (25 September 1996); doi: 10.1117/12.252111; https://doi.org/10.1117/12.252111