7 May 1997 Compact, rugged, and inexpensive frequency-domain fluorometer
Ralph Levy, Ernest F. Guignon, Sean Cobane, Ernest St. Louis, Salvador M. Fernandez
Author Affiliations +
Proceedings Volume 2980, Advances in Fluorescence Sensing Technology III; (1997) https://doi.org/10.1117/12.273571
Event: BiOS '97, Part of Photonics West, 1997, San Jose, CA, United States
Abstract
Fluorescence-based fiber-optic sensors are the subject of considerable interest because of their high sensitivity and excellent specificity and versatility. Currently, most fluorescence sensors use UV or visible excitation and are based on intensity measurements; i.e. the emission intensity of the fluorescent indicator changes in response to binding of analyte or to some other variable of interest. While intensity-based sensors may be easy to implement in a controlled laboratory environment they are often difficult in real-world situations because of photobleaching, sample turbidity, fluorophore washout, and fouling of optical surfaces. Another drawback of intensity-based sensing is the problem of referencing the intensity measurements. A promising approach to obviate many of these problems is fluorescence lifetime sensing. Fluorescence lifetimes are exquisitely sensitive to the microenvironment of the fluorophore. Additionally, lifetime measurements are robust, being highly immune to photobleaching, and to changes in fluorophore concentration, exciting light intensity, optical density of the sample, detector sensitivity, fouling of optical surfaces, etc. Despite these advantages, the complexity, size, and high cost of currently available instrumentation for measuring fluorescence lifetimes presents a major barrier to practical implementation of lifetime-based sensors. In this paper we describe a compact, simple-to-use, inexpensive phase fluorometer suitable for sensor applications.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ralph Levy, Ernest F. Guignon, Sean Cobane, Ernest St. Louis, and Salvador M. Fernandez "Compact, rugged, and inexpensive frequency-domain fluorometer", Proc. SPIE 2980, Advances in Fluorescence Sensing Technology III, (7 May 1997); https://doi.org/10.1117/12.273571
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Luminescence

Sensors

Modulation

Phase shift keying

Fluorometers

Signal generators

Semiconductor lasers

Back to Top