3 November 1997 Multilayer spherical grating monochromator for 1- to 4-KeV x rays
Author Affiliations +
Abstract
In this paper we discuss the design and anticipated optical performance of a multilayer spherical grating monochromator for x- rays with energies of 1-4 keV. The monochromator is to be used for x-ray microscopy and coherence experiments on the 2-IDB soft x-ray beamline at the Advanced Photon Source. The layout, design considerations, and resolving power with various single and multilayer grating coatings are discussed.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ian McNulty, Yipeng Feng, Sean P. Frigo, Timothy M. Mooney, "Multilayer spherical grating monochromator for 1- to 4-KeV x rays", Proc. SPIE 3150, Gratings and Grating Monochromators for Synchrotron Radiation, (3 November 1997); doi: 10.1117/12.292733; https://doi.org/10.1117/12.292733