3 November 1997 Multilayer spherical grating monochromator for 1- to 4-KeV x rays
Author Affiliations +
Abstract
In this paper we discuss the design and anticipated optical performance of a multilayer spherical grating monochromator for x- rays with energies of 1-4 keV. The monochromator is to be used for x-ray microscopy and coherence experiments on the 2-IDB soft x-ray beamline at the Advanced Photon Source. The layout, design considerations, and resolving power with various single and multilayer grating coatings are discussed.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ian McNulty, Ian McNulty, Yipeng Feng, Yipeng Feng, Sean P. Frigo, Sean P. Frigo, Timothy M. Mooney, Timothy M. Mooney, } "Multilayer spherical grating monochromator for 1- to 4-KeV x rays", Proc. SPIE 3150, Gratings and Grating Monochromators for Synchrotron Radiation, (3 November 1997); doi: 10.1117/12.292733; https://doi.org/10.1117/12.292733