Paper
11 December 1997 Beryllium window for an APS diagnostics beamline
I. C. Albert Sheng, Bingxin X. Yang, Sushil Sharma
Author Affiliations +
Abstract
A beryllium (Be) window for an Advanced Photon Source diagnostics beamline has been designed and built. The window, which has a double concave axisymmetrical profile with a thickness of 0.5 mm at the center, receives 160 W/mm2 (7 GeV/100 mA stored beam) from an undulator beam. The window design as well as thermal and thermomechanical analyses, including thermal buckling of the Be window, are presented.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
I. C. Albert Sheng, Bingxin X. Yang, and Sushil Sharma "Beryllium window for an APS diagnostics beamline", Proc. SPIE 3151, High Heat Flux and Synchrotron Radiation Beamlines, (11 December 1997); https://doi.org/10.1117/12.294471
Lens.org Logo