You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
11 December 1997Beryllium window for an APS diagnostics beamline
A beryllium (Be) window for an Advanced Photon Source diagnostics beamline has been designed and built. The window, which has a double concave axisymmetrical profile with a thickness of 0.5 mm at the center, receives 160 W/mm2 (7 GeV/100 mA stored beam) from an undulator beam. The window design as well as thermal and thermomechanical analyses, including thermal buckling of the Be window, are presented.
The alert did not successfully save. Please try again later.
I. C. Albert Sheng, Bingxin X. Yang, Sushil Sharma, "Beryllium window for an APS diagnostics beamline," Proc. SPIE 3151, High Heat Flux and Synchrotron Radiation Beamlines, (11 December 1997); https://doi.org/10.1117/12.294471