21 November 1997 Whole-field instantaneous 3D PIV measurement in air
Author Affiliations +
Abstract
A 3D measurement is presented of both the in-plane and out- of-plane components of the flow field velocity of 0.5 micrometers styrene particles at 30 ms-1 in air from a calibrated nozzle by using a co-linear side scattering PIV approach. The light sheet used to illuminate the particles was generated using a Nd:YAG laser, operating in triple pulse mode. The scattered light from the particle was imaged through a near diffraction limited lens. The particle images have been analyzed from both their respective diffraction patterns and from their out of focus intensity profile. The authors show that the co-linear 3D PIV method can be used to determine the particle velocity in three directions. Results have been presented for different flow angles through a calibration 30ms-1 air jet, showing that it is possible to identify the particle position in three directions, within a turbulent flow, to a spatial accuracy of +/- 20 micrometers .
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Wing Kai A. Lee, Wing Kai A. Lee, L. S. Judge, L. S. Judge, Mark Burnett, Mark Burnett, Doina Daciana Udrea, Doina Daciana Udrea, Peter John Bryanston-Cross, Peter John Bryanston-Cross, } "Whole-field instantaneous 3D PIV measurement in air", Proc. SPIE 3172, Optical Technology in Fluid, Thermal, and Combustion Flow III, (21 November 1997); doi: 10.1117/12.293411; https://doi.org/10.1117/12.293411