Paper
16 November 1982 InSb Charge-Injection Device Array Performance
A. M. Fowler, J. P. Britt
Author Affiliations +
Abstract
Low temperature tests of the G. E. 32x1 and 32x32 InSb CID arrays were carried out to evaluate their potential for use in infrared astronomical instruments. The tests revealed that the arrays could be operated at⪅20°X. with dark currents low enough that integration times of up to 1 hour would be possible. Responsivities up to 1.8 AN for the linear array and 0.4 AN for the area array. at 3.6 microns were observed dropping to 0.9 AN and 1.2 AN respectively at 4.7 microns. The linear array exhibited a troublesome response lag at low flux levels which, limits its usefulness and the area array usefulness will be limited by its higher noise level.
© (1982) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. M. Fowler and J. P. Britt "InSb Charge-Injection Device Array Performance", Proc. SPIE 0331, Instrumentation in Astronomy IV, (16 November 1982); https://doi.org/10.1117/12.933434
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Electrodes

Capacitance

Astronomy

Quantum efficiency

Scanners

Amplifiers

Back to Top