Abstract
Pre-stressed concrete water pipelines are commonly helically wrapped with highly stressed wire. Although passivated by use of high pH concrete coating, these wires can corrode and break, ultimately resulting in catastrophic failure of the pipe. The failure of these wires releases stored acoustic energy into the walls of the pipes, and into their contents. Continuous acoustic monitoring of the water column in the pipe using various methods can reveal the condition and rate of deterioration of the pipe. This paper discuses the evidence that the method is workable, and suggests a three-stage approach to efficiently examine long pipelines with no interruption in service.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Peter O. Paulson "Three-stage monitoring of prestressed concrete pipelines", Proc. SPIE 3398, Nondestructive Evaluation of Utilities and Pipelines II, (15 March 1998); https://doi.org/10.1117/12.302524