Abstract
A DF cw laser system is used an an example to illustrate the requirements for HEL diagnostics. The laser device performance parameters are identified, with primary diagnostics being near field power, near field irradiance, wavelength, angular beam jitter, and beam quality. A variety of component/subsystem diagnostics are reviewed, for the gain generator, optical resonator, diffuser/ejector and fluid supply subsystems. Methods of characterizing these subsystems, as well as approaches to the primary diagnostics, provide an adequate data base for understanding the high energy laser system.