Paper
19 November 1998 Joint AXAF high-resolution mirror assembly and AXAF CCD Imaging Spectrometer calibration at the MSFC X-Ray Calibration Facility
John A. Nousek, Leisa K. Townsley, George Chartas, David N. Burrows, E. Moskalenko, R. Sambruna, J. Pesce, Catherine E. Grant, Kaori Nishikida, Laura J. Cawley, Patrick Sean Broos, Scott Koch, A. Garmire, Gordon P. Garmire, Mark W. Bautz, Stephen E. Jones, Beverly LaMarr, George R. Ricker Jr.
Author Affiliations +
Abstract
The flight AXAF CCD Imaging Spectrometer (ACIS) and the High-Resolution Mirror Assembly (HRMA) telescope were extensively calibrated at NASA MSFC's X-Ray Calibration Facility (XRCF). We present result based on HRMA/ACIS characteristics that were obtained with the following tests: (a) Point-Spread Function (PSF) tests measuring the core and wings of the PSF on-axis and at several off-axis positions, at the point of ideal focus. (b) Effective-Area (EA) test measuring the total effective collecting area over the PSF at many energies. We investigate the dependence of the effective area and energy response of ACIS/HRMA as a function of several ACIS parameters. (c) Count-rate- linearity (pile-up) test measuring the effect of increasing the mean incident rat of photons per pixel on the PSF, and EA, source centroid, and photon detection. The goal of the calibration is to provide accurate estimates of the in-orbit performance of the ACIS/HRMA instrument and to enable translation of in-orbit measurements to absolute values of the incident x-ray flux and physical models of the source emission.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
John A. Nousek, Leisa K. Townsley, George Chartas, David N. Burrows, E. Moskalenko, R. Sambruna, J. Pesce, Catherine E. Grant, Kaori Nishikida, Laura J. Cawley, Patrick Sean Broos, Scott Koch, A. Garmire, Gordon P. Garmire, Mark W. Bautz, Stephen E. Jones, Beverly LaMarr, and George R. Ricker Jr. "Joint AXAF high-resolution mirror assembly and AXAF CCD Imaging Spectrometer calibration at the MSFC X-Ray Calibration Facility", Proc. SPIE 3444, X-Ray Optics, Instruments, and Missions, (19 November 1998); https://doi.org/10.1117/12.331239
Lens.org Logo
CITATIONS
Cited by 14 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

Point spread functions

Calibration

Photons

X-rays

Data modeling

Mirrors

RELATED CONTENT

Imaging performance of the XMM-Newton x-ray telescopes
Proceedings of SPIE (July 18 2000)
In-flight calibration of the SWIFT XRT effective area
Proceedings of SPIE (August 18 2005)
The calibration of the Solar-B x-ray optics
Proceedings of SPIE (August 24 2005)
Flight x ray CCD selection for the AXAF CCD Imaging...
Proceedings of SPIE (October 31 1996)
SWIFT XRT point spread function measured at the Panter end...
Proceedings of SPIE (February 03 2004)

Back to Top