13 November 1998 Metrology of a mirror at the Advanced Photon Source: comparison between optical and x-ray measurements
Author Affiliations +
Abstract
This paper describes metrology of a vertically focusing mirror on the bending magnet beamline in sector-1 of the Advanced Photon Source, Argonne National Laboratory. The mirror was evaluated using measurements from both an optical long trace profiler and x-rays. Slope error profiles obtained with the two methods were compared and were found to be in a good agreement. Further comparisons were made between x-ray measurements and results from the SHADOW ray-tracing code.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lahsen Assoufid, Lahsen Assoufid, Jonathan C. Lang, Jonathan C. Lang, Jin Wang, Jin Wang, George Srajer, George Srajer, } "Metrology of a mirror at the Advanced Photon Source: comparison between optical and x-ray measurements", Proc. SPIE 3447, Advances in Mirror Technology for Synchrotron X-Ray and Laser Applications, (13 November 1998); doi: 10.1117/12.331123; https://doi.org/10.1117/12.331123