Abstract
Deep X-ray lithography with synchrotron radiation (DXRL) represents the technological core of the LIGA technique, which is a modem microfabrication technology facilitating the high volume production of micro products from a huge variety of materials. Since several applications make use of the high structure accuracy obtained in the primary lithography process, the demands of a detailed investigation of structure accuracy limiting aspects came to rise. Therefore, thorough theoretical and experimental research has been undertaken in order to understand the different radiation effects influencing the shape of the side walls and the lateral resolution to be obtained. Physical effects like diffraction, divergence of the synchrotron radiation beam, photo and Auger electrons, fluorescence and scattering have been calculated and are condensed in a computer code. The calculation results are discussed in detail with respect to LIGA mask production by x-ray lithography as well as for deep x-ray lithography applications. The model can be partially extended to new irradiation techniques like tilted and rotated exposures. Different absorber gradients due to various tilt angles have to be taken into account and the resulting dose contour lines resulting from inclined irradiations are compared with experimental data. In order to enhance the normal shadow printing process and to realize shaping in the third dimension, previous studies used the aligned multiple exposure technique realizing step like structures. We will discuss a novel approach using 500 m thick Beryllium mask blanks with free standing absorber structures (gold) on open windows for alignment purposes. First results show an overlay accuracy of about 0.4 tm using an internal alignment system installed in a DEX 2 JENOPTIK exposure apparatus.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Andreas Schmidt, Wolfgang Ehrfeld, Gregor Feiertag, Regina Luettge, and Martin Schmidt "Pattern transfer accuracy in deep x-ray lithography: calculation and experimental results", Proc. SPIE 3512, Materials and Device Characterization in Micromachining, (1 September 1998); https://doi.org/10.1117/12.324067
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photomasks

Luminescence

X-ray lithography

Gold

Beryllium

Optical alignment

Polymethylmethacrylate

RELATED CONTENT

Prototyping for high aspect ratio MEMS by high energy x...
Proceedings of SPIE (September 03 1999)
Microfabrication of PLLA polymer by x-ray lithography
Proceedings of SPIE (December 20 2006)
Mask technologies for deep x-ray LIGA
Proceedings of SPIE (May 28 2003)
Thick silicon membranes as mask blank for SU 8 x...
Proceedings of SPIE (August 20 2001)

Back to Top