Paper
22 June 1999 Experimental estimation of S-1 photocathode beam strength
Author Affiliations +
Proceedings Volume 3516, 23rd International Congress on High-Speed Photography and Photonics; (1999) https://doi.org/10.1117/12.350487
Event: Twenty-Third International Congress on High-Speed Photography and Photonics, 1998, Moscow, Russian Federation
Abstract
The threshold value of the energy density qthr at wavelength of 1.06 micrometer which led to unrecoverable sensitivity loss of the first generation S-1 photocathode of single-chamber module image converter tube (ICT) with fiber disks at input and output was determined experimentally. The value amounted to 2 X 10-2J/cm2.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vitaly B. Lebedev "Experimental estimation of S-1 photocathode beam strength", Proc. SPIE 3516, 23rd International Congress on High-Speed Photography and Photonics, (22 June 1999); https://doi.org/10.1117/12.350487