You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
1 February 1999Embeddable sensor for corrosion measurement
The design of a microinstrument for corrosion monitoring in reinforced concrete is presented and the performance of the prototype device discussed. Sensors for the measurement of corrosion rate, corrosion potential, chloride concentration, and concrete conductivity have been developed and tested inside of model concrete slabs. The tests include electrochemical chloride driving as a method for test acceleration and wet/dry cycling. The corrosion rate and conductivity sensors perform very well, as do all aspects of the electronics. Work continues on the chloride sensor and reference electrode.